MP Series 67 models 672 and 674 are now validated to an interrupt capacity of 5000 A @ 28 VDC. With that rating, they're designed for main battery disconnect applications.
Series 67 is our small-frame battery selector/disconnect switch with an integrated circuit breaker. Until now, most customers have used it for auxiliary circuits like windlass or trolling motors and accessory loads. The new rating means it can do more: switching and protecting the main battery circuit in a single compact unit.
A main battery disconnect has a harder job than an auxiliary switch. It sits between the battery bank and the rest of the electrical system, so it has to safely interrupt the full fault current a battery can deliver.
At 5000 A @ 28 VDC, the 672 and 674 have the headroom for that job. Builders and upfitters can now use one compact switch, with circuit protection built in, for the main disconnect, not just for the windlass, trolling motor or accessory circuit.
Nothing about the Series 67 design has changed. What's new is our ability to prove what it can do.
We recently built a new test lab that can test to higher ratings than ever before. We're putting it to work on designs our customers already know and trust, validating higher ratings on existing products.
Series 67 is the first to benefit:
Same switch, same footprint, same part numbers. Higher validated ratings.
| Model | Configuration | 42 VDC | 28 VDC | 14 VDC |
|---|---|---|---|---|
| 672 | Type 2: Single Input ON/OFF (2 position) | 1500 A | 5000 A | — |
| 673 | Type 3: Dual Plus with Combine (3 position) | 1500 A | — | 3000 A |
| 674 | Type 4: Dual Input (4 position) | 1500 A | 5000 A | — |
In every configuration, the ACC ("House") circuit is always protected by the integrated breaker.
The higher ratings come in the same compact, rugged package:
Series 67 is suited for Marine, Truck, Bus, RV, Con-Ag and Commercial vehicle applications. With the 672 and 674 now designed for main battery disconnect applications, one product line covers both the main disconnect and the auxiliary circuits.
This is just the start. Our new lab lets us keep validating higher ratings on the products you already rely on, and we'll share each one as it's complete.
The updated Series 67 datasheet (QC-4017-F) is available at MP S67 Datasheet. For application support or samples, contact your MechProd rep or email helpme@mechprod.com.